Laboratory base

Laboratory base
The testing laboratory is equipped with a stand for testing the reaction to fire of materials and products used in land, sea, road and rail constructions (see the chart). Technical equipment provides research in accordance with the requirements of the applicable: regulations, national and international standards.
Research stands are equipped with multi-integrated measurement and control systems. Our specialist measuring software is written in the convention of test procedures. Performing test, at every stage of research process, receives results of the validity check of action of the position and results of measurements appropriate and information concerning activities which one should carry out in the given moment.

  

The list of research stands

  

Method description
1
   
Stand for testing the non-combustibility of materials with a method according to:
PN-EN ISO 1182,
IMO 2010 FTP Code Part 1
2
  
Stand for determination of the gross heat of combustion of materials with a method according to PN-EN ISO 1716


3

  

   
Stand for testing reaction to fire of building materials with a method according to PN-EN 13823 (SBI - Single Burning Item)


4
   
Stand for determination of the floorings burning behaviour with methods according to  
PN-EN ISO 9239-1,
PN-EN 45545-2.
5
  
Stand for testing the ignitability of building products and materials with methods according to  
PN-EN ISO 11925-2,
PN-EN 45545-2.

6
  
Stand for testing surface flammability  of materials with methods according to  
ISO 5658-2,
IMO 2010 FTP Code Part 5


7
  
Stand for testing heat release rate and smoke production rate of materials with methods according to
ISO 5660-1,
IMO 2010 FTP Code Part 10,
PN-EN 45545-2


8
  
Stand for testing reaction to fire of furniture with methods according to  
PN ISO/TR 9705,
PN-EN 45545-2, Annex B  
PN-EN 16989
(furniture calorimeter)


9
  
Stand for standard vandalism test for seat coverings with methods according to
EN 45545-2, Annex A
EN 45545-2, Annex B,
PN-EN 16989

10

  

  
Stand for standard vandalism test for seat coverings with method according to NF F 00-201

11
  
Stand for testing reaction to fire of materials by a method of “Brandschacht” (fire shaft) according to
DIN 4102 part  15,
DIN 4102 part 16
DIN 4102 part 1 (class B1)
12
  
Stand for testing the ignitability of materials with methods according to  
DIN 53438 part 2,
DIN 53438 part 3
DIN 4102 part 1 (class B2)


13

  

  
Stand for testing burning behaviour of materials by oxygen index with a method according to PN-EN ISO 4589-2


14
  
Stand for testing smoke generation of materials and the toxicity of the products of their decomposition and combustion with methods according to  
PN-EN 45545-2,
IMO 2010 FTP Code Part 2,
ISO 5659-2


15

  

  
Stand for testing the toxicity of the decomposition and combustion products of materials with a method according to polish standard PN-B-02855


16
  
Stand for testing the toxicity of the decomposition and combustion products of materials with a methods according to
NF X70-100-1,
NF X70-100-2,
PN-EN 45545-2,
PN-EN 50305.


17
  
Stand for testing the toxicity of the products of decomposition and combustion of cables with a method according to
PN-EN 50305,
PN-EN 45545-2.


18
  
Stand for determining the horizontal burning rate of interior motor vehicle materials with a methods according to
PN ISO 3795,
Appendix 6 of Regulation no. 118 EKG
19

  

  
Stand for determining the melting behaviour of materials with a method according to
Appendix 7 of Regulation no. 118 EKG


20
  
Stand for determining the vertical burning rate of interior materials with a methods according to
PN-EN ISO 6941,
Appendix 8 of Regulation no. 118 EKG,
21
  
Stand for testing the ignitability of upholstered furniture with methods according to
PN-EN-1021-1,
PN-EN-1021-2,
BS 7176,
IMO 2010 FTP Code Part 8


22
  
  
Stand for the testing the assessment of  ignitability of bedding items, mattresses and upholstered divans with methods according to  
PN-EN 597-1,
PN-EN 597-2,
PN-EN ISO 12952-1,
PN-EN ISO 12952-2,
BS 7177,
IMO 2010 FTP Code Part 9

23
  
  
Stand for testing the ignitability of upholstered furniture with methods according to  
BS 5852,
BS 7176

24
  
  
Stand for testing the ignitability of complete items of furniture with methods according to BS 5852

25
  
  
Stand for the testing the assessment of  ignitability of mattresses, upholstered divans and upholstered bed bases with methods according to  
BS 6807,
BS 7176,
BS 7177

26
   
  
Stand for testing reaction to fire of vertically oriented specimens (textile fabrics) with a method in accordance with PN-EN ISO 6940

27
  
  
Stand for testing reaction to fire of vertically oriented specimens (textile fabrics and foils) with a method in accordance with IMO 2010 FTP Code Part 7

28
  
  
Stand for testing limited flame spread of protective closing with a methods in accordance with  
PN EN ISO 15025,
BS 5867 Part 2

29
  
  
Stand for testing the assessment of  ignitability of materials with glow - wire test methods according to  
PN-EN 60695-2-10,
PN-EN 60695-2-11,
PN-EN 60695-2-12,
PN-EN 60695-2-13,
PN-EN 45545-2.

30
   
  
Stand for testing the assessment of  ignitability of materials/products with needle – flame test methods according to PN-EN 60695-11-5

31
  
  
Stand for testing the assessment of  ignitability of materials/products with 50 W flame test methods according to  
PN-EN 60695-11-10,
UL 94,
PN-EN 45545-2.

32
  
  
Stand for testing the assessment of  ignitability of materials/products with 500 W flame test methods according to  
PN-EN 60695-11-20,
UL 94

33
   
  
Stand for testing susceptibility of charcoal self-heating in accordance to MSC 79/23/Add.4

34
  
  
Stand for testing effect on inflammability of wood after treatment wood  by wood preservatives according to PN-C-04914

35
  
  
Stand for burning rate test of  readily combustible solids in accordance to ADR - European Agreement Concerning the International Carriage of Dangerous Goods by Road


biuro@sychta.eu